Self-priming centrifugal pumps are unique. As the name suggests, they have the ability to prime themselves under suction lift conditions.  They draw fluid up from tanks or pits below, making them easier and safer to work on than those that work below ground. Under the right conditions, they’ll free themselves of entrained gas and function normally on their own, but sometimes, they can’t. 

HOW A SELF PRIMING PUMP WORKS

A BRIEF NOTE OF CAUTION: Just because self-priming pumps able to pull fluid into them, doesn’t mean that they should start up dry. Self-priming, centrifugal pumps need fluid in the casing to get started. Running dry, even for a short while, will cause damage to the mechanical seal, and pump failure.

Once the pump is turned on, the impeller begins to turn in a counter clockwise rotation. The fluid inside, or the “initial prime”, flows through the volute into the discharge cavity. Here, the air and fluid separate, the air evacuates through an open ended line, or air release line, while the fluid returns to the impeller through a recirculation port.

While the fluid is recirculated and the air is removed from the discharge cavity, low pressure is being created at the eye of the impeller. Atmospheric pressure is higher than the lower pressure created at the eye of the impeller, thus fluid is forced up the suction line.

As fluid moves up the suction line, the air ahead of the fluid is pushed into the casing and handled as the initial prime was handled through the recirculation process. Once the fluid arrives in the pump, it operates as normal.

This video from Gorman-Rupp does a great job showing how a self-priming pump works.

 

That’s how it’s supposed to work. If that’s not the case for you, here are some reasons why your self-priming pump might not prime.

WHY YOUR SELF-PRIMING PUMP WON’T PRIME

1. AIR LEAK IN SUCTION LINE

As fluid recirculates in the pump and forces air out of the discharge chamber, it’s trying to create an area of low pressure. However, if there’s a leak in the suction line, air continues to be drawn into the pump, never allowing it to release enough to create that area of low pressure.

2. DEBRIS IN THE IMPELLER

If the eye of then impeller is plugged with debris, it removes the hydraulic capability of the impeller to create an area of low pressure.

3. PUMP IS AIR BOUND

A pump can become air-bound if it experiences any of these conditions:

  • NO AIR RELEASE LINE
    If there is no air release line, air cannot be vented to the atmosphere, and instead collects on the discharge side.

  • THE DISCHARGE LINE IS PRESSURIZED
    If a valve on the air release line is closed, and the valve on the discharge line is closed, again, it's giving no place for the air to go and get out of the pump.

  • EXCESSIVE IMPELLER CLEARANCE
    If there is excessive clearance between the impeller and the wear plate, the pump has a difficult time creating a low-pressure area. This is typically caused by wear, but could also be due to improper reassembly.
4. PLUGGED RECIRCULATION PORT

During the priming process, as discussed above, fluid is recirculated through the volute casing. If the recirculation port becomes plugged, the eye of the impeller is unable to create an area of low pressure in which to pull liquid up the suction line.

5. LIFT TOO HIGH FOR PUMP SPEED OR IMPELLER DIAMETER
If you’ve undersized the pump for the suction line, it will not be able to create the low-pressure area it needs to prime. It’s important to understand the suction lift requirements before selecting a pump for the application. Use Gorman-Rupp’s Pump Selection Guide for the calculations you’ll need.  

The ability for self-priming pumps to prime hinges on all the right conditions. The pump must be able to evacuate air from inside the pump, create a low-pressure area at the eye of the impeller, and also be properly sized for the right NPSH conditions.

Expert Centrifugal Pump Insights from Crane Engineering

Engineers and experts rely on Crane Engineering for insight and help with centrifugal pumps and positive displacement pumps. Our in-house team of engineers can answer questions related to not only pumps but valves and skid systems. We provide a complete service and repair team who will fix pumps back to OEM standards. We are ready to assist you if you're in Wisconsin, Minnesota, Iowa, North Dakota, South Dakota, and the Upper Peninsula of Michigan. Crane Engineering also builds and designs customized skid systems nationwide so contact us, today! 